This page is updated routinely to show exciting, new products being introduced to the market place.
We have also provided a direct link to each manufacturer's website to download more details including brochures, manuals, etc. Just click on the picture!
|
AURA Gas Controls is our newest product line of precision Pressure Regulators. The precision comes into play by the metal-to-metal seals made during the machine manufacturing and by using an exclusive "encapsulated cartridge" with 10 micron filter. There are thus only six parts to this entire regulator!
The cartridge could be replaced in the field if desired without removing the regulator from the piping.
Products include single & dual stage units, with pressure, back pressure & vacuum regulators as desired. There is also a vaporizing regulator for converting liquids to a gas for measurement. The Switchover System will precisely monitor one gas cylinder pressure delivery and then automatically "switch over" to the standby cylinder when the time comes, thereby insuring 100% continuous service without interruption and using as much of the expensive Cal Gas as possible in the bottle.
All regulators are assembled in a Clean Room environment with Oxygen cleaning, and then 100% tested with Helium prior to shipment. All regulators are provided with a LIFETIME WARRANTY.
|
 |
AURA Gas Controls Regulator w/Gauges |
|
|
 |
640i & 780i Mass Flow Meters |
|
| World’s Most Accurate Thermal Mass Flow Meters (Sierra Instruments) • Accuracy: +/- 0.5% of reading at calibration conditions (50% to 100% of full scale flow) • DrySense eliminates drift, assures long term accuracy and stability of flow meter • QuadraTherm’s four-sensor design isolates forced convection (critical variable for measuring gas mass flow rate), by neutralizing unwanted heat transfer, like sensor stem conduction, one of the major causes of false flow readings. (See the Sierra Thermal Video on our Training page. • AeroMax™ sensor head eliminates probe downdrafts and false flows
• Multivariable: Get mass flow rate, temperature and pressure from a single 3/4 inch insertion point with the 640i; Dial-A-Pipe allows for field configeration for different pipe sizes; Dial-A-Gas allows for field programming for different gases.
• 780i in-line version has built-in flow conditioning for a repeatable flow profile requiring only minimal upstream and downstream pipe runs
|
EMERSON Process Management: Oxygen (O2) Combustion Transmitter
AccuMax enhanced system performance
- Accuracy ±0.75% of reading or ±0.05% oxygen
- Signal stability of ±0.03% oxygen
- Insensitive to process temperature changes ±0.02% from 100-700°C
- Calibration validity of better than 0.02%
- Adaptable to most existing oxygen probe installations for lengths of 18", 3ft, 6ft, 9ft, 12ft, 15ft, & 18ft;
- 2-wire, loop-powered electronics & standard HART communications
- Extended process temperature range to 850°C (1562°F); Inquire for higher temperatures up to 2900F.
- Advanced sensor diagnostics, including "calibration recommended"
- Two-year sensing cell warranty
- AMS/PlantWeb® compatible with EDDL
|
 |
Oxymitter 4000/ 6888 |
|
|
 |
Model 56 Analyzer |
|
| EMERSON Process Measurement (Rosemount)
- MULTI-PARAMETER INSTRUMENT- with dual sensor inputs. Choose from any combination of pH/ORP/ISL, Resistivity/Conductivity, % Concentration, Chlorine (Residual or Free Chlorine, Monochloramine), Oxygen, Residual Ozone, Temperature, and Turbidity.
- OUTPUTS include multiple 4-20mA, HART, and four Alarm Relays
- DATA LOGGING for up to 30 days of process data, and download via the onboard USB2 data port to Flash Drive.
- LARGE COLOR DISPLAY – large, easy-to-read process measurements and Graphical Chart Recorder of data. "SMART" Detection of Sensor & Calibration Data, once a SMART Sensor is connected.
- EASY TO INSTALL – modular boards; removable connectors easy to wire power, sensors, and outputs.
- INTUITIVE MENU SCREENS with advanced diagnostics and help screens.
- SIX LANGUAGES are included with every analyzer: English, French, German, Italian, Spanish, and Portuguese.
- DIAGNOSTICS - continuously monitors itself and the sensor(s) for problematic conditions. The display flashes Fault and/or Warning when these conditions occur. Information about each condition is quickly accessible by pressing the diagnostic button on the keypad. Help screens are displayed for most fault and warning conditions to guide the user in troubleshooting.
|
 |
Series 100 MFC |
|
From Sierra Instruments: Mass Flow Controllers & Meters
"Dial-A-Gas" and true digital performance in the latest generation MFC: Series 100.
Designed for both OEM customers and end-users, SmartTrak offers accurate, reliable performance, an easy-to-use interface, rugged stainless steel construction, and maximum flexibility. Unlike most analog Mass Flow Controllers (MFC) that are built to order for specific gases and flow ranges, SmartTrak lets you select from up to 10 gases and adjust operating parameters to accommodate unexpected application or system design changes. The instrument is also available as a mass flow meter and now in several sizes & configurations for flow rates from 0-10 SCCM to 0-1000 SLPM.
|
|
BADGER (Data Industrial) Sensors
SDI insert style flow sensors are intended for general flow measurement applications such as in HVAC, potable water, and irrigation use since they can handle small amounts of particulate in the line like sand. They are available in either brass or stainless steel construction. The insert style sensors are intended for direct installation into pipelines through a 1" tap.
Two models are available, to be powered either via 24VDC, Loop-Power having a 4-20mA output signal or
by an internal Lithium Battery (5 year life) for remote locations like irrigation farms that just want a digital display for Rate & Total, which toggles.
For the Direct Insertion, the pipeline must be out of service and not under pressure at the time of installation.
For a pressurized pipe in service at the time of installation, Badger recommends the use of our SDI "Hot Tap" models that are equipped with an isolation ball valve for insertion/removal.
Standard sensor stem lengths accommodate pipe sizes from 1½" through 48" in diameter.
Accuracies of +/-1 % of Rate are typical.
The picture to the left shows a close-up of the 316SS impeller with Tungsten Carbide shaft, Torlon bearing, and Viton O-ring for long life service.
|
 |
SDI Impeller - closeup |
|
|
|